Safety Glazing Explained: The 800mm Rule

Safety Glazing Explained: The 800mm Rule
One area that is often overlooked in windows and doors regulations is when safety glass is legally required. Often it is thought that as long as you have safety glass in doors then your house is sorted, however as you will read below there’s more to it than that.
Here’s the correct, simple explanation based on the latest UK Building Regulations.
🔍 The 800mm Rule
Under Building Regulations Part K, safety glazing is required wherever glass is:
✔ Below 800mm from the floor
✔ Or within 300mm horizontally of a door and below 1500mm in height
✔ Or in any glass used within a door up to 1500mm high
These are called “critical locations”.
💡 So What About Bathrooms?
A bathroom is not automatically a critical location but it is often an area that is over looked.
The 800mm rule also applies from any place you could reasonably stand — not just the floor.
This includes:
- Standing in a bath
- Standing on a shower tray
- Standing on a built‑in window seat
- Standing on a platform or raised step
🛡 Types of Safety Glass Allowed
Part K accepts several forms of “safe breakage” glass including:
- Toughened glass – BS EN 12150‑1 (Glass shatters into small blunt granules when broken)
- Laminated glass – BS EN 14449 (Glass stays bonded and in place when broken)
All safety glass should have a permanent stamp marking on the glass – usually in one of the corners.

👍 Where You’ll Commonly See Safety Glass
- Patio doors & French doors
- Full‑height conservatory glazing
- Large fixed panels
- Low‑level windows
- Bathroom windows below 800mm
- Porch doors
- Side panels next to doors
⭐ In Summary
Safety glazing isn’t optional — it’s a legal requirement in all critical locations. The key measurement is height, not room type.
When we survey your property, we automatically check all glazing heights to ensure every installation complies with Part K. https://yatewindows.co.uk